C11000 Copper Strip in Coil is a high-purity electrolytic tough pitch (ETP) copper product known for its excellent electrical conductivity, thermal conductivity, and good ductility. With a minimum copper content of 99.90%, C11000 copper strip offers reliable performance, making it suitable for a wide range of electrical and industrial applications.
As a professional C11000 copper strip coil supplier, we provide copper strips in various thicknesses, widths, coil weights, and tempers to meet different manufacturing requirements. Our products feature consistent quality, excellent conductivity, and good formability, making them ideal for electrical connectors, busbars, transformers, switchgear, power distribution systems, and electronic components.
We offer customized specifications, slitting services, and other processing options according to customer requirements. Whether you need narrow copper strips for precision components or wider copper coils for industrial manufacturing, our C11000 copper strip in coil provides a reliable material solution for your business.
What Is C11000 Copper Strip in Coil?
C11000 copper strip in coil (also known as T2 red copper coil strip, Cu-ETP, electrolytic tough pitch copper) is a pure copper strip containing ≥99.90% Cu+Ag with controlled oxygen content of 0.02–0.06%. It is supplied in continuous coil form for high-volume processing.
Why it is called "T2 red copper": In the Chinese standard GB/T 5231, T2 is the designation for electrolytic tough pitch copper. The "red copper" name comes from its characteristic reddish color - distinct from brass (yellow) and cupronickel (silver-white).
The key performance advantage: C11000 delivers 100% IACS electrical conductivity - the highest of any standard commercial copper - with excellent thermal conductivity and good cold working properties. This makes it the default choice for transformer windings, busbars, connectors, and current-carrying components.
Material Specifications (ASTM B152 / B888)
| Property | Value | Remarks |
|---|---|---|
| UNS / Common Names | C11000 / ETP Copper / Cu-ETP | ASTM B152 (Sheet/Strip/Coil) |
| Composition | Cu ≥99.90%; O₂ ~200–400 ppm | Contains residual oxygen |
| Electrical Conductivity | 100–101% IACS | Annealed condition |
| Thermal Conductivity | ~390 W/(m·K) | Exceptional heat transfer |
| Density | 8.89–8.94 g/cm³ | |
| Hydrogen Embrittlement | Susceptible | Must not be heated in H₂ or reducing atmospheres |
| Surface Finish | Bright, degreased, oxidation-free | Ready for continuous stamping or plating |
👉 Request a C11000 Copper Coil Quotation
C11000 vs C10200 vs C12200: Which Copper Coil Strip Do You Need?
| Property | C11000 (T2 / ETP) | C10200 (TU1/TU2 / OF) | C12200 (TP2 / DHP) |
|---|---|---|---|
| UNS | C11000 | C10200 | C12200 |
| Oxygen Content | 0.02–0.06% | ≤0.001% | ≤0.040% (deoxidized) |
| Electrical Conductivity | 100% IACS | 100–101% IACS | ~85% IACS |
| Hydrogen Embrittlement | Susceptible >370°C | Immune | Resistant |
| Weldability | Good (brazing/soldering) | Excellent | Excellent |
| Cost | Lowest | Higher | Higher |
| Key Advantage | Best conductivity at lowest cost | No hydrogen embrittlement | Weldability + hydrogen resistance |
| Typical Use | Transformers, busbars, connectors | Vacuum components, welding | HVAC, heat exchangers, brazed assemblies |
- Choose C11000 (T2) for transformer windings, busbars, connectors, and general electrical applications where cost and conductivity are priorities.
- Choose C10200 (TU1/TU2) when the strip will be welded, brazed, or used in reducing atmospheres where hydrogen embrittlement must be eliminated.
- Choose C12200 (TP2) for brazed or joining-sensitive production - the phosphorus deoxidation resists hydrogen embrittlement while maintaining good conductivity.
Why Buyers Choose Us as Their C11000 Copper Strip Supplier
- Custom slit widths to your specification. We slit from 30 mm to 1500 mm width, with tight tolerances for transformer winding and busbar stamping .
- Burr-controlled edges. We control burr height and perform edge conditioning for transformer winding applications where insulation integrity is critical .
- Verified 100% IACS conductivity. Every shipment includes a Mill Test Report with full chemistry and conductivity testing. Guaranteed minimum 100% IACS .
- Clean, oxide-free surface. Low-residue lubricants or dry-slitting available. Wrapped securely for moisture and tarnish protection .
- Multiple tempers in stock. R220 (annealed), R240, R290, and R360 tempers available to match your forming and strength requirements .
- Fast delivery from stock. Standard sizes ship in 3–5 working days for stock material; custom slit confirmed at order review .
- Technical support for strip selection. Not sure whether C11000 or C10200 is right for your brazing process? Send us your application details - we will recommend the right grade.
Buyer's Guide: How to Avoid Procurement Pitfalls
| Risk | What to Check | Action |
|---|---|---|
| Bad edge tears insulation | Burr height on slit edges | Request micrograph edge documentation |
| Camber causes loose windings | Lateral curvature along coil length | Specify camber limit - typically within 0.005 inches |
| Low conductivity raises losses | Verified % IACS | Request MTR with conductivity testing |
| Surface contamination | Slitting oils, dust, oxidation | Specify low-residue or dry-slitting |
| Mixed grades | Actual copper content | Request batch-specific MTC and PMI verification |
| Wrong grade for welding | Hydrogen embrittlement risk | Choose C10200 for reducing atmosphere service |
👉 Send Your C11000 Coil Specification for a Quotation
Typical Applications
- Transformer Windings: Distribution transformers, power transformers, instrument transformers
- Busbars & Conductive Strips: Switchgear, panelboards, power distribution
- Connectors & Terminals: Stamped connectors, terminals, spring contacts
- Motors & Generators: Commutator strips, winding strips
- Heat Exchangers: Brazed plate heat exchangers, HVAC components
- Decorative & Architectural: Roofing strips, art and architectural elements
Our Factory
Copper Strip Production Line

Copper Strip Production Line China Manufacturer HSMetal

Copper Strip Slitting Equipment

Copper Coil Strip Slitting In Production Line

Brass Strip Cutting Workshop

Brass Strip Production Equipment

Brass Strip Slitting Equipment
Commercial and Delivery Terms
| Item | Specification |
|---|---|
| Material Grade | C11000 (T2 Red Copper) Copper Strip in Coil |
| MOQ | 200 KG for custom slit C11000 copper strip in coil; small trial order acceptable |
| Lead Time | 7‑14 working days for standard custom slit T2 red copper coil strip |
| Trade Terms | EXW, FOB(Shanghai, Qingdao or any of China Ports), CFR, CIF |
| Payment Terms | T/T 30% deposit, 70% before shipment; L/C at sight for large orders |
| Export Documents | Commercial Invoice, Packing List, Mill Test Certificate(MTC) |
| Packaging | VCI anti‑rust paper, moisture‑proof plastic film, seaworthy fumigated wooden pallets |
| Shipment Port | Main China seaports |
Need C11000 Copper Strip in Coil for Your Transformer, Busbar, or Connector Application?
Tell us your required grade (C11000, C10200, or C12200), thickness, width, temper, coil weight, quantity, and application. We will confirm availability, provide a quotation, and ship with full documentation.
👉 Contact HSMetal for Alloy Selection Support
Explore our other copper products → C11000 Copper Bar | C10200 Oxygen-Free Copper | C12200 DHP Copper | Copper Busbar
FAQ
Q1: What is the difference between C11000 copper strip in coil and T2 red copper coil strip?
A: C11000 copper strip in coil is the UNS designation; T2 red copper coil strip is the corresponding Chinese standard grade. They stand for the same ETP pure copper material widely used for transformers, busbars and electrical connectors.
Q2: Can you provide custom slit C11000 copper strip in coil according to my required width for electrical connectors and busbars?
A: Yes. Our core service is custom slit T2 red copper coil strip. Please provide target width, thickness, tolerance and temper of your C11000 copper strip in coil for transformers, busbars or electrical connectors.
Q3: Which temper of C11000 copper strip in coil suits transformer winding, busbars and electrical connectors?
A: Choose O soft annealed T2 red copper coil strip for transformer winding that needs heavy bending. Select 1/2H for general‑purpose busbars and electrical connectors; pick H hard temper if high rigidity is required for busbar applications of C11000 copper strip in coil.
Q4: Will C11000 copper strip in coil get oxidized during long ocean shipping?
A: Our standard VCI moisture‑proof packaging greatly lowers oxidation risk for T2 red copper coil strip. For long‑haul humid shipment, anti‑tarnish oil treatment is recommended for your C11000 copper strip in coil.
Q5: Can you do custom slitting for C11000 copper strip in coil?
A: Yes. Custom slitting is our core service. We can slit T2 red copper coil strip to your exact target width, with controllable edge condition for transformers, busbars and connectors production. Please share your drawing or dimension requirement for quotation.
Q6: What is C11000 copper strip in coil used for?
A: C11000 copper strip in coil is used for transformer coils, busbars, terminal connectors, electrical contacts, switches, radio parts, heat sinks, and deep drawn components. It is chosen when you need maximum electrical conductivity (100% IACS) at the lowest cost .
Q7: What is the difference between C11000 and C10200?
A: C11000 contains 0.02–0.06% oxygen; C10200 is oxygen-free (≤0.001%). Both deliver 100% IACS conductivity. C11000 is cheaper and machines slightly better; C10200 is immune to hydrogen embrittlement and is preferred for vacuum brazing, welding, and electronic applications . Choose C11000 for standard electrical strip; choose C10200 for reducing atmosphere service.
Q8: What is the electrical conductivity of C11000?
A: C11000 delivers 100% IACS electrical conductivity in the annealed condition - the highest of any standard commercial copper grade. Thermal conductivity is 394 W/(m·K) .
Q9: What is the hydrogen embrittlement risk of C11000?
A: C11000 contains oxygen. In reducing atmospheres above 370°C (such as hydrogen brazing or certain welding processes), the oxygen reacts with hydrogen to form steam at grain boundaries, causing internal cracks . Avoid C11000 for welding-critical applications; specify C10200 (oxygen-free) instead.
Q10: What tempers are available for C11000 strip?
A: Available tempers include R220 (Annealed), R240, R290, and R360 . Soft temper offers maximum ductility for deep drawing and bending; Hard temper offers higher strength for structural applications.
Q11: Can C11000 strip be welded?
A: Welding is not recommended for C11000 due to hydrogen embrittlement risk. Soldering and brazing are excellent - C11000 is widely used for soldered electrical connections .
Q12: What is the maximum service temperature of C11000?
A: C11000 is suitable for continuous service up to approximately 200°C in air. Above this, oxidation increases. Avoid reducing atmospheres above 370°C due to hydrogen embrittlement risk .
Hot Tags: C11000 Copper Strip in Coil, C11000 copper coil, ETP copper strip in coil, C11000 vs C10100, C11000 vs C12200, pure copper coil for stamping, continuous copper strip, HSMetal